Pepperl Fuchs KFD2-UT2-Ex1 Universal Temperature Converter (248764)
The P&F KFD2-UT2-Ex1 is a 1-channel isolated barrier designed for safe and efficient temperature signal transmission in hazardous areas. Accepting input from thermocouples, RTDs, voltage, or potentiometers, it provides an isolated 0/4 mA to 20 mA output in sink or source mode. The unit is easily configured via PACTware software and supports line fault detection, sensor burnout detection, and is certified up to SIL 2 per IEC 61508/61511.
Technical Specifications
- Model: KFD2-UT2-Ex1
- Function: Universal Temperature Converter
- Input Types: Thermocouple, RTD, Voltage (±100 mV), Potentiometer
- Output: 0 … 20 mA / 4 … 20 mA (sink or source)
- Configuration: PACTware (via programming socket)
- Cold Junction Compensation: Optional with K-CJC-** terminal block
Electrical Characteristics
- Supply Voltage: 20 … 30 V DC (via Power Rail or terminals 14+, 15–)
- Power Consumption: ≤ 0.98 W
- Output Terminals: 7–9 (configurable sink/source)
- Output Load (Source Mode): 0 … 550 Ω
- Open-Circuit Voltage: ≤ 18 V
- Fault Signal: 0, 2 mA (downscale), 21.5 mA (upscale per NAMUR NE43)
Input Types & Ranges
- RTDs: Pt10, Pt50, Pt100, Pt500, Pt1000, Cu10, Cu50, Cu100, Ni100 (2-, 3-, 4-wire)
- Thermocouples: B, E, J, K, N, R, S, T, L, TXK, TXKH, TXA
- Voltage: Selectable ±100 mV (≥ 1 MΩ input resistance)
- Potentiometer: 0 … 20 kΩ (2-wire), 0.8 … 20 kΩ (3-wire)
Performance & Accuracy
- Pt100 Accuracy: ±(0.06% of value + 0.1% span + 0.1 K)
- Thermocouple Accuracy: ±(0.05% + 0.1% span + 1 K)
- Voltage Accuracy: ±50 µV + 0.1% of span
- Potentiometer Accuracy: ±0.05% FS + 0.1% span
- Ambient Temperature Drift: up to ±0.006%/K
- Reaction Time: 800 ms – 2.05 s depending on input type
Environmental & Mechanical
- Operating Temperature: –20 … +60 °C
- Protection: IP20
- Mounting: 35 mm DIN rail (EN 60715)
- Dimensions: 20 × 119 × 115 mm (W × H × D)
- Weight: Approx. 130 g
Hazardous Area Certifications
- Zones: Zone 0, 1, 2 / Div. 1, 2
- ATEX Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
- IECEx Marking: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I / Ex nA IIC T4 Gc
- Maximum Safe Voltage (Um): 250 V
- Galvanic Isolation: 375 V peak (input/output/supply)
Key Features & Benefits
✅ Wide Sensor Compatibility: Supports RTDs, TCs, potentiometers, and voltage signals.
✅ Fully Programmable: Easy setup via PACTware with LED diagnostics.
✅ Sink or Source Output: Configurable to match system requirements.
✅ Fail-Safe Indication: NAMUR NE43-compliant fault signaling.
✅ SIL 2 Certified: Ideal for safety-critical applications.
📦 Buy Pepperl+Fuchs KFD2-UT2-Ex1 from Drive Outlet Megastore
At Drive Outlet Megastore we offer unbeatable KFD2-UT2-Ex1 prices on Pepperl+Fuchs universal temperature converters.
This compact, feature-rich unit is perfect for hazardous area signal transmission, supporting a broad range of sensor inputs with superior accuracy and safety certification.
UK stock, fast DHL delivery, and 2-year warranty included.
Contact us now to get a quote or request the full datasheet.



Reviews