Motor Starter Selection Calculator
Compare Direct-On-Line (DOL), star-delta, soft starter and variable frequency drive starting methods for your electric motor. Get a preliminary recommendation based on motor specifications and application requirements.
Enter Your Motor Specifications
Complete the fields below to compare motor starting methods. Use the actual motor nameplate current and connection details wherever available.
Your Motor Starter Results
Compare Motor Starting Methods
Each starting method has different electrical and mechanical characteristics. Choose according to the motor and load, not simply the motor power.
Direct-On-Line (DOL)
Connects the motor directly to its rated supply voltage. Simple and cost-effective, but typically produces high inrush current and starting torque. Requires suitable electrical protection and an acceptable starting impact.
Star-Delta Starting
Starts a suitable three-phase motor in star before changing to delta. Approximate initial starting current and torque can be around one-third of direct-on-line values for the same supply voltage. It is generally unsuitable for high starting-torque loads.
Soft Starter
Controls voltage during starting and stopping to reduce electrical and mechanical transients. Starting torque also decreases as voltage is reduced, so the selected model must meet the load’s acceleration and duty requirements.
Variable Frequency Drive (VFD)
Controls motor frequency and voltage for variable-speed operation and controlled acceleration. It is often useful for demanding starts and process-speed control when correctly configured for the motor and application.
What Affects Starter Selection?
Motor Rated Current
Motor nameplate current is a critical input when selecting a starter, overload relay or contactor. Always use the actual motor ratings when available.
Starting Torque & Load Inertia
Some applications need substantial torque from standstill. Star-delta and reduced-voltage starters may be unsuitable if the available torque is insufficient to accelerate the load.
Starts Per Hour
Frequent starting increases electrical and thermal stress. Check the complete starting duty cycle, acceleration time and manufacturer-rated starts per hour.
Supply & Motor Connection
Star-delta requires a compatible three-phase motor designed to run in delta at the supply voltage, with access to the required winding connections.
Related Engineering Calculators
Continue your motor-control selection using our free engineering tools.
Motor Starter FAQs
When should I use a DOL starter?
DOL starting can be appropriate when the supply network and mechanical equipment can tolerate the motor’s starting current and torque. Suitability is not determined by a universal motor-kW threshold.
Is star-delta starting better than DOL?
It depends on the application. Star-delta reduces starting current but also substantially reduces starting torque. It needs a compatible motor and an appropriate starting load.
Can a soft starter be used for heavy-duty motors?
Yes, where the selected soft starter is rated for the load and starting duty. High-torque applications require particular attention to the starting torque and current limit.
Does a soft starter control motor speed?
A conventional soft starter primarily controls starting and stopping. For continuous variable-speed control, a suitable VFD is generally the appropriate choice.
Can I use star-delta on a single-phase motor?
No. Conventional star-delta starting applies to suitable three-phase motors with the necessary winding connections.
Need Help Selecting a Motor Starter?
Send us your motor nameplate details, starting duty, supply voltage and application requirements. Our team can help investigate compatible soft starters, drives and motor-control equipment.