Braking Resistor Calculator
Estimate regenerative braking energy, peak braking power and resistor thermal requirements for an industrial VFD system. Use your drive specifications to assess a preliminary braking-resistor range.
Enter Your Braking Requirements
Accurate braking resistor selection depends on the energy removed during deceleration. Enter total rotating inertia referred to the motor shaft, operating speed and the required stopping interval.
Your Braking Calculation Results
Preliminary deceleration estimates based on the entered rotating inertia and speed.
How Braking Resistor Sizing Works
The resistor dissipates recovered energy as heat when the inverter’s braking circuit directs regenerative energy to it.
Enter the rotational speed before deceleration.
Account for rotor and reflected load inertia.
Estimate energy, braking power and repetition.
Verify resistance, chopper power and thermal ratings.
Important Selection Considerations
Braking-Chopper Compatibility
Your VFD must support an external braking resistor, either through an internal chopper or an appropriate external braking unit. Check the manufacturer’s minimum resistance, switching voltage and maximum braking power.
Resistor Energy and Thermal Ratings
A resistor needs sufficient energy capacity for each braking pulse and adequate continuous and intermittent thermal capacity for the duty cycle. An average-wattage figure alone is not enough to establish suitability.
Overhauling and Vertical Loads
Hoists, lowering loads and other overhauling systems can generate additional energy from gravity or driven machinery. Rotational kinetic energy alone is not a complete model for these applications.
Related Engineering Calculators
Explore our other free drive and motor selection tools.
Braking Resistor FAQs
How do I calculate braking resistor size?
Determine braking energy, peak braking power and repetitive duty. Then select an appropriate resistance, pulse energy rating and thermal capacity using the inverter manufacturer’s specifications.
Can I calculate resistance from motor kW alone?
No. Motor power does not tell you the total inertia or regenerative energy. The inverter’s braking-chopper specifications must also be considered.
Does a shorter stopping time require more power?
For the same energy and an otherwise comparable deceleration, reducing stopping time increases braking power. It may exceed the capability of the drive or resistor.
Can I use a lower-ohm resistor for stronger braking?
Only within the manufacturer’s permitted resistance range. A resistor below the drive’s minimum resistance can overload or damage the braking chopper.
Does every inverter support a braking resistor?
No. Some drives need a separate braking unit, while others do not support external resistor braking. Check the exact drive model and manual.
Need Help Selecting a Braking Resistor?
Send us the inverter part number, motor power, braking time and application details. Our team can investigate compatible braking resistor options.