Braking Resistor Calculator

Estimate regenerative braking energy, peak braking power and resistor thermal requirements for an industrial VFD system. Use your drive specifications to assess a preliminary braking-resistor range.

Free Engineering Calculator Instant Braking Estimates Industrial VFD Applications No Registration Required
01

Enter Your Braking Requirements

Accurate braking resistor selection depends on the energy removed during deceleration. Enter total rotating inertia referred to the motor shaft, operating speed and the required stopping interval.

Used as a reference for the motor and drive rating, not to invent inertia.
Helps identify your drive voltage class. Not the braking-chopper threshold.
Used for contextual warnings, not arbitrary energy multipliers.
Time to decelerate from the entered speed to zero.
Motor-shaft speed before braking starts.
Motor rotor plus load inertia referred to the motor shaft. Include gearing.
Used to estimate average heat dissipation.
Use 100% unless the braking-energy split is supported by application data.
OPTIONAL — INVERTER BRAKING-CHOPPER DETAILS
Enter the actual braking switching voltage, not the AC motor voltage.
Critical inverter limit. Never select a resistor below this value.
Do not know the inertia? The calculator cannot produce a dependable braking-energy estimate without it. Your machine manufacturer, gearbox design data or mechanical engineer may be able to supply the total reflected inertia.
02

Your Braking Calculation Results

Preliminary deceleration estimates based on the entered rotating inertia and speed.

Energy Per Stop —
Average Resistor Thermal Power —
Average Power During Stop —
Approximate Braking Duty —
03

How Braking Resistor Sizing Works

The resistor dissipates recovered energy as heat when the inverter’s braking circuit directs regenerative energy to it.

STEP 01 Motor Speed

Enter the rotational speed before deceleration.

STEP 02 Total Inertia

Account for rotor and reflected load inertia.

STEP 03 Stopping Duty

Estimate energy, braking power and repetition.

STEP 04 Drive Limits

Verify resistance, chopper power and thermal ratings.

04

Important Selection Considerations

Braking-Chopper Compatibility

Your VFD must support an external braking resistor, either through an internal chopper or an appropriate external braking unit. Check the manufacturer’s minimum resistance, switching voltage and maximum braking power.

Resistor Energy and Thermal Ratings

A resistor needs sufficient energy capacity for each braking pulse and adequate continuous and intermittent thermal capacity for the duty cycle. An average-wattage figure alone is not enough to establish suitability.

Overhauling and Vertical Loads

Hoists, lowering loads and other overhauling systems can generate additional energy from gravity or driven machinery. Rotational kinetic energy alone is not a complete model for these applications.

05

Related Engineering Calculators

Explore our other free drive and motor selection tools.

06

Braking Resistor FAQs

How do I calculate braking resistor size?

Determine braking energy, peak braking power and repetitive duty. Then select an appropriate resistance, pulse energy rating and thermal capacity using the inverter manufacturer’s specifications.

Can I calculate resistance from motor kW alone?

No. Motor power does not tell you the total inertia or regenerative energy. The inverter’s braking-chopper specifications must also be considered.

Does a shorter stopping time require more power?

For the same energy and an otherwise comparable deceleration, reducing stopping time increases braking power. It may exceed the capability of the drive or resistor.

Can I use a lower-ohm resistor for stronger braking?

Only within the manufacturer’s permitted resistance range. A resistor below the drive’s minimum resistance can overload or damage the braking chopper.

Does every inverter support a braking resistor?

No. Some drives need a separate braking unit, while others do not support external resistor braking. Check the exact drive model and manual.