Pepperl Fuchs KFD2-UT2-Ex2 Universal Temperature Converter (248767)
The P&F KFD2-UT2-Ex2 is a dual-channel isolated barrier that converts thermocouple, RTD, voltage, or potentiometer signals into proportional analog current outputs. Designed for hazardous areas, this unit features two configurable outputs and can function as a signal splitter (1 input to 2 outputs). Ideal for intrinsic safety applications, it is fully programmable via PACTware and includes SIL 2 compliance, line fault detection, and cold junction compensation support.
Technical Specifications
- Model: KFD2-UT2-Ex2
- Function: Dual-Channel Universal Temperature Converter with Signal Splitter Mode
- Input Types: RTD, Thermocouple, Voltage, Potentiometer
- Output: 0 … 20 mA or 4 … 20 mA (Sink or Source, 2 outputs)
- Configuration: PACTware via programming socket
- Cold Junction Compensation: External/Internal using K-CJC-** accessory
Electrical Characteristics
- Supply Voltage: 20 … 30 V DC (via Power Rail or terminals 14+, 15–)
- Power Consumption: ≤ 1.53 W
- Output Terminals:Output I: terminals 7–9Output II: terminals 10–12
- Source Load: 0 … 550 Ω
- Open-Circuit Voltage: ≤ 18 V
- Fault Signal: 0, 2 mA (downscale) or 21.5 mA (upscale per NAMUR NE43)
Input Types & Ranges
- RTDs: Pt10, Pt50, Pt100, Pt500, Pt1000, Cu10/50/100, Ni100 (2- or 3-wire)
- Thermocouples: B, E, J, K, N, R, S, T, L, TXK, TXKH, TXA
- Voltage: –100 mV to +100 mV (≥ 1 MΩ input resistance)
- Potentiometer: 0 … 20 kΩ (2-wire) or 0.8 … 20 kΩ (3-wire)
Performance & Accuracy
- RTD Accuracy: ±(0.06% value + 0.1% span + 0.1 K)
- TC Accuracy: ±(0.05% value + 0.1% span + 1 K) or 1.2 K for R/S types
- mV Accuracy: ±(50 µV + 0.1% span)
- Potentiometer Accuracy: ±(0.05% FS + 0.1% span)
- Temperature Drift: up to ±0.006%/K
- Reaction Time: 0.92–2.8 s depending on input type
Environmental & Mechanical
- Operating Temperature: –20 … +60 °C
- Protection: IP20
- Mounting: 35 mm DIN rail (EN 60715)
- Dimensions: 20 × 119 × 115 mm (W × H × D)
- Weight: Approx. 130 g
Hazardous Area Certifications
- Zones: Zone 0, 1, 2 / Div. 1, 2
- ATEX Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
- IECEx Marking: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I / Ex nA IIC T4 Gc
- Maximum Safe Voltage (Um): 250 V
- Galvanic Isolation: 375 V peak (input/output/supply)
Key Features & Benefits
✅ Dual Outputs: Supports signal splitting for redundant or parallel system monitoring.
✅ Extensive Sensor Compatibility: Accepts thermocouples, RTDs, voltage, and potentiometers.
✅ PACTware Configurable: Fast, flexible parameterization and diagnostics.
✅ SIL 2 Compliant: Meets functional safety standards for process-critical applications.
✅ LED Diagnostics: NAMUR NE44 fault indication and collective error output.
📦 Buy Pepperl+Fuchs KFD2-UT2-Ex2 from Drive Outlet Megastore
At Drive Outlet Megastore we offer unbeatable KFD2-UT2-Ex2 prices.
With advanced signal splitting capability and broad sensor input support, it’s perfect for modern process control systems in hazardous areas.
Available with fast delivery and full 2-year warranty.





Reviews