SICK RLY3-TIME100 Safety Relay Module (1100688)

£356.44

⚡ Request a Live Quote — we’ll check today’s live pricing and send our best offer.

  • Time-Delayed Safety Stop: Adjustable delay from 0.1 to 30 seconds for controlled system shutdown.
  • High Safety Certification: SIL3, PL e, and Category 4 compliance for critical applications.
  • Compact and Slim Design: 18 mm width ideal for space-saving panel installations.
  • Reliable Mechanical Life: 10 million switching cycles for long-term operation.
  • Diagnostic Outputs: Push-pull outputs for system health and fault monitoring.
📦 Fast UK Delivery

In stock now, delivered in 3–5 working days — most orders arrive in 3–4 days. Fully tracked and insured.


🛡️ 24-Month Drive Outlet Warranty
Every product is 100% new, genuine, and backed by our exclusive 2-year warranty. We are an independent supplier and not an authorised distributor. Manufacturer warranties may not apply. See our Terms and Conditions.
SKU: RLY3-TIME100 Category: Tags: , Brand:
Guaranteed Safe Checkout
Extra Features
  • 100% Brand New & Genuine OEM Product
  • Includes Full 2-Year Warranty for Peace of Mind
  • Fast UK & Worldwide Shipping – Fully Tracked
  • Expert Technical Support from Our In-House Engineers
  • Found a Better Price? We’ll Match or Beat It Instantly

SICK RLY3-TIME100 Safety Relay Module (1100688)

The SICK RLY3-TIME100 is a versatile safety relay designed for stop category 1 applications requiring time-delayed shutdowns. Compatible with safety sensors featuring OSSDs or potential-free contacts, it provides SIL3 and PL e level safety, ensuring maximum protection for personnel and machinery in demanding industrial environments.


Technical Specifications

Model: RLY3-TIME100 SICK
Part No.: 1100688
Product Type: Safety Relay Module
Applications: Evaluation unit for stop category 1 functions, suitable for sensors with OSSDs or potential-free outputs


Safety-Related Parameters

Safety Integrity Level (SIL): SIL 3 (IEC 61508)
Performance Level (PL): PL e (ISO 13849-1)
Category: Category 4 (ISO 13849-1)
PFHD (Mean Probability of Dangerous Failure per Hour): Extremely low
Mission Time (TM): 20 years (ISO 13849-1)


Electrical Data

Voltage Supply (VS): 24 V DC (16.8 V to 30 V DC, PELV or SELV)
Residual Ripple: ≤ 2.4 V
Power Consumption: ≤ 2.5 W

Safety Inputs:

  • Number: 2
  • Input Voltage High: 24 V DC (11 V to 30 V)
  • Input Voltage Low: 0 V DC (–3 V to 5 V)
  • Input Current: 4 mA to 6 mA
  • Test Pulse Width: ≤ 1 ms
  • Test Pulse Rate: ≤ 10 Hz

Reset Pushbutton / EDM Input:

  • Number: 1
  • Same input parameters as safety inputs

Activation Time Tolerance Between Start Buttons: ≤ 3 s


Output Data

Immediate Enabling Current Paths:

  • Number: 2 N/O contacts (positively guided)
  • Switching Voltage: 10 V AC/DC to 230 V AC/DC
  • Switching Current: 10 mA to 6 A
  • Total Current: 12 A combined
  • Mechanical Life: 10 million switching cycles

Time-Delayed Enabling Current Path:

  • Response Time: Adjustable from 0.1 s to 30 s
  • Switching Voltage: 10 V DC to 30 V DC
  • Switching Current: 2 mA to 2 A
  • Mechanical Life: 10 million switching cycles

Diagnostic Outputs:

  • Number: 2
  • Type: Push-pull semiconductor, short-circuit protected
  • Output Voltage High: ≥ VS – 3 V
  • Output Voltage Low: ≤ 3 V
  • Output Current (PNP): ≤ 120 mA

Test Pulse Output:

  • Number: 1
  • Type: PNP semiconductor, short-circuit protected
  • Test Pulse Width: 2 ms
  • Test Pulse Interval: 40 ms

Mechanical Data

Enclosure Rating: IP20 (for use inside control panels)
Housing Material: Plastic
Dimensions (W x H x D): 18 mm × 124.6 mm × 85.5 mm
Weight: Approx. 160 g
Mounting: Standard DIN rail (35 mm)


Ambient Conditions

Operating Temperature: –25 °C to +55 °C
Storage Temperature: –40 °C to +70 °C
Relative Humidity: 90%, non-condensing
Vibration Resistance: Complies with IEC 60068-2-6
Shock Resistance: Complies with IEC 60068-2-27


Certificates and Compliance

  • European Conformity (CE)
  • UKCA Certification
  • cULus Listed (UL 508)
  • China Compulsory Certification (CCC)
  • RoHS Compliance

Applications

Ideal For:

  • Safety shutdown with controlled delay (stop category 1)
  • Machine stopping after critical operations
  • Conveyor, packaging, and robotic cell shutdowns
  • Dual-channel emergency stop buttons
  • Monitoring of safety sensors with OSSDs or potential-free contacts

Key Features & Benefits

Time-Delayed Safety Stop: Adjustable delay from 0.1 to 30 seconds for controlled system shutdown.

High Safety Certification: SIL3, PL e, and Category 4 compliance for critical applications.

Compact and Slim Design: 18 mm width ideal for space-saving panel installations.

Reliable Mechanical Life: 10 million switching cycles for long-term operation.

Diagnostic Outputs: Push-pull outputs for system health and fault monitoring.


📦 Order Today for Fast UK & Europe Delivery!

At Drive Outlet Megastore, we offer unbeatable SICK RLY3-TIME100 prices and fast dispatch across the UK and Europe.

Need expert help configuring your machine’s stop functions? Our certified safety specialists are ready to assist!

Stop safely, operate smarter — with SICK and Drive Outlet Megastore.


Weight 2.5 kg

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

SICK Supplier UK – Industrial Sensors, Safety & Detection Parts

Browse SICK products for photoelectric sensing, laser measurement, encoders, safety devices, distance sensors, machine detection and industrial automation replacement jobs.

⚙️ Genuine OEM Automation Parts
🔎 Search by Part Number
🚚 Fast UK & International Delivery
🛠️ Technical Sourcing Support

Popular SICK Products

Use the product links below as quick routes into this brand. If you already know your part number, use the search bar for the fastest result.


Shop SICK by Product Category, Series & Specification

Compare SICK sensors by sensing type, detection range, output, connection, housing style, safety rating, switching logic and exact manufacturer part number.


Need Help Finding the Right SICK Product?

If you cannot find the exact part number, send us the model code, a photo of the rating plate or the details of the machine it is fitted to. We can help check availability, replacements and suitable alternatives.


SICK FAQs

How do I find the correct SICK product?

The fastest way is to search using the exact manufacturer part number or model code. You can also browse this brand page by product category, series and specification to compare close alternatives.

What should I check before buying SICK products?

Check the exact SICK part number, sensing range, output type, connector, supply voltage, mounting style, safety rating and whether the replacement matches the original detection method.

Can you help if my exact SICK part number is not listed?

Yes. Send us the part number, a photo of the label or the machine details and we can check availability, replacement options and suitable alternatives.

Are these products suitable for industrial replacement jobs?

These pages are designed for maintenance teams, panel builders, OEM buyers and engineers who need part-number-led industrial automation spares for repairs, upgrades and breakdown support.

How quickly can you supply SICK products?

Availability depends on the exact product and quantity required. Check the product page or contact us and we can confirm stock position, lead time and shipping options.

View all SICK products

Need help specifying the correct safety solution?

Share your safety function and wiring requirements — we’ll advise on compatible safety relays/devices.

  • Safety function and wiring guidance
  • Compatible accessories and options
  • Fast quote with suitable alternatives