Pepperl Fuchs KFD2-SR2-Ex1.W.LB Switch Amplifier (203351)
The P&F KFD2-SR2-Ex1.W.LB is a 1-channel intrinsically safe switch amplifier with dual relay outputs and line fault detection, designed for transferring digital signals from NAMUR sensors or dry contacts in hazardous areas to safe-zone control systems.
Featuring reversible logic, collective error signaling via Power Rail, and DIP switch configuration, this device is certified up to SIL 2 (SC 3) and ideal for high-reliability applications in process automation.
Technical Specifications
Model: KFD2-SR2-Ex1.W.LB
Type: Intrinsically Safe Switch Amplifier
Input Type: NAMUR sensor or dry contact
Output Type: Dual relay contact outputs (signal & fault)
Channels: 1
Mounting: 35 mm DIN rail (EN 60715)
Input Specifications
- Connection Terminals: 1+, 2+, 3-
- Standard: EN 60947-5-6 (NAMUR)
- Open Circuit Voltage: Approx. 8 V DC
- Short-Circuit Current: Approx. 8 mA
- Switching Point: 1.2 … 2.1 mA
- Hysteresis: Approx. 0.2 mA
- Line Fault Detection: Break ≤ 0.1 mA, Short ≥ 6 mA
- Pulse/Pause Ratio: Min. 20 ms
Output Specifications
- Output Terminals: I: 7, 8, 9 | II: 10, 11, 12
- Output Type: Relay contact (signal + fault)
- Contact Rating:
- 250 V AC / 2 A (cos φ > 0.75)
- 126.5 V AC / 4 A (cos φ > 0.75)
- 40 V DC / 2 A resistive
- Minimum Switching Current: 2 mA @ 24 V DC
- Switching Delay: Approx. 20 ms (On/Off)
- Mechanical Life: 107 switching cycles
Power & Configuration
- Supply Voltage: 19 … 30 V DC
- Rated Current: ≤ 45 mA
- Power Dissipation: ≤ 0.9 W
- Power Rail Support: Yes
- Visual Indicators: LEDs (NAMUR NE 44)
- Configuration: DIP switch configurable
Galvanic Isolation
- Input/Output: Reinforced (300 Veff)
- Input/Power Supply: Reinforced (300 Veff)
- Output/Power Supply: Reinforced (300 Veff)
- Output/Output: Reinforced (300 Veff)
Environmental & Mechanical
- Operating Temperature: -40 … 70 °C
- Degree of Protection: IP20
- Connection: Screw terminals
- Dimensions: 20 x 119 x 115 mm (W x H x D)
- Weight: Approx. 150 g
Certifications & Safety
- SIL Rating: SIL 2 (SC 3) per IEC/EN 61508
- ATEX Marking: II (1)G [Ex ia Ga] IIC / II (1)D [Ex ia Da] IIIC / I (M1) [Ex ia Ma] I
- IECEx Marking: Ex ia Ga IIC / Ex ia Da IIIC / Ex ia Ma I / Ex ec nC IIC T4 Gc
- FM/UL Approval: Yes (FM19US0207X, UL E106378)
- Certificates: PTB 00 ATEX 2080, TÜV 99 ATEX 1493 X, IECEx PTB 11.0034, IECEx TUN 19.0013X
- Max Safe Voltage (Um): 253 V AC / 125 V DC (signal), 40 V DC (fault)
Key Features & Benefits
✅ Dual Relay Output: Handles signal and fault outputs separately.
✅ Power Rail Ready: Enables collective fault messaging via DIN rail.
✅ Safe Isolation: Reinforced galvanic separation across all interfaces.
✅ SIL 2 Functional Safety: Certified for safety-critical applications.
✅ Compact Design: Fits standard DIN rail enclosures for efficient wiring.
📦 Buy Pepperl+Fuchs KFD2-SR2-Ex1.W.LB from Drive Outlet Megastore
At Drive Outlet Megastore we offer unbeatable KFD2-SR2-Ex1.W.LB prices.
Delivers safe, redundant signal transfer with dual outputs and built-in fault monitoring. It’s ideal for interfacing NAMUR sensors in Ex zones while maintaining safe zone integrity.
In stock now and available with 2–3 days delivery.


Reviews
There are no reviews yet.